Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Trace Element (TE)Release as Nutritional Supplement of daily Needs From Three Different dental Alloys in Vitro Simulation of Dental Plague (CROSBI ID 484779)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa

Miko, Slobodan ; Čelebić, Asja ; Baučić, Ivo ; Čatić, Alma, Rinčić, Nives ; Baučić, Maja ; Stipetić, Jasmina Trace Element (TE)Release as Nutritional Supplement of daily Needs From Three Different dental Alloys in Vitro Simulation of Dental Plague // Collegium antropologicum. 2002. str. 136-136

Podaci o odgovornosti

Miko, Slobodan ; Čelebić, Asja ; Baučić, Ivo ; Čatić, Alma, Rinčić, Nives ; Baučić, Maja ; Stipetić, Jasmina

engleski

Trace Element (TE)Release as Nutritional Supplement of daily Needs From Three Different dental Alloys in Vitro Simulation of Dental Plague

Over 90% of adult population (>35 y) in Croatia wear dental crowns and/or fixed with partial dentures (FPD) and in 30% of population FPDs are combined with metal frame removable partial dentures (RPD). The aim of this work was to assess how TE leached from crown/bridge Au-Pt metal alloy, niCr alloy for dental ceramics and from CoCrMo alloy for RPD-m in simulated dental plague. We soaked ten sets of Au-Pt alloy pieces having 133 mm2 exposure surface each, ten sets of CcCrMo alloy pieces and ten sets of NiCr alloy pieces having 497 mm2 exposure surface each, from 1 to 30 days (six replicates each)in lactic acid (pH 3.5). TE were assessed by ICP-AES (JY50P, Jobin-Ivon, France detection limit 10micrograms/L. from the Au-Pt alloy (refinary of precious metals, Zagreb, Croatia) were released in lactic acid( mean ; SD)Zn, 140 (47), Cu 113 (79), Fe 58(36), and Cr(<10). From the CoCrMo (Wironit, Bego, Germany) (mean ; SD): Co 501(400), Fe 133(360), Zn 78(39), Ni 34 (60) and Cr 65(121) of TE were released. The NiCr alloy (Wiron99, Bego, Germany)(mean ; SD): Co 339(318), Fe 227(272), Zn 96(51), Ni 432 (502) and Cr 368 (361) were released, The manufacturers did not indicate the presence of all the elements release from each alloy. Some of the TE were released in concentrations that exceed daily essential needs for human health, which may be of interest to nutritionists, After laboratory procedures TEs may be released in higher amount and other TE may become detectable, However, the considerable amounts of essential albeit allergenic essential TE Cr, Co, and Ni may be present locally.

Au-Pt alloy ; NiCr alloy ; trace elements ; simulated dental plague

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

136-136.

2002.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Collegium antropologicum

Zagreb:

0350-6134

1848-9486

Podaci o skupu

13th Congress of the European Anthropological Association

poster

30.08.2002-03.09.2002

Zagreb, Hrvatska

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost