Theoretical determination of elasticity constants for steam boiler membrane wall as the structurally orthotropic plate (CROSBI ID 195108)
Prilog u časopisu | prethodno priopćenje | međunarodna recenzija
Podaci o odgovornosti
Sertić, Josip ; Gelo, Ivan ; Kozak, Dražan ; Damjanović, Darko ; Konjatić, Pejo
hrvatski
Theoretical determination of elasticity constants for steam boiler membrane wall as the structurally orthotropic plate
This paper presents theoretical determination of elasticity constants for steam boiler membrane wall as structurally orthotropic plate. Modulus of elasticity and shear modulus are determined in directions parallel and perpendicular to membrane wall pipes for both bending and membrane load. When determining modulus of elasticity for bending load, Engesser's theorem is used for obtaining deflection of membrane wall. After that, from equality of deflections of membrane wall and structurally orthotropic plate, modulus of elasticity is obtained. When determining modulus of elasticity for membrane load, Engesser's theorem is also used, and the expression is obtained from extension equation of membrane wall and structurally orthotropic plate. Shear modulus for both loading conditions are obtained using Poisson's ratios.
Elasticity constants ; Membrane wall ; Steam boiler ; Structurally orthotropic plate
nije evidentirano
engleski
Theoretical determination of elasticity constants for steam boiler membrane wall as the structurally orthotropic plate
This paper presents theoretical determination of elasticity constants for steam boiler membrane wall as structurally orthotropic plate. Modulus of elasticity and shear modulus are determined in directions parallel and perpendicular to membrane wall pipes for both bending and membrane load. When determining modulus of elasticity for bending load, Engesser's theorem is used for obtaining deflection of membrane wall. After that, from equality of deflections of membrane wall and structurally orthotropic plate, modulus of elasticity is obtained. When determining modulus of elasticity for membrane load, Engesser's theorem is also used, and the expression is obtained from extension equation of membrane wall and structurally orthotropic plate. Shear modulus for both loading conditions are obtained using Poisson's ratios.
Elasticity constants ; Membrane wall ; Steam boiler ; Structurally orthotropic plate
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
20 (4)
2013.
697-703
objavljeno
1330-3651
1848-6339