Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Improvement of fuel oil spray combustion inside a 7 MW industrial furnace : A numerical study (CROSBI ID 231193)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bonefačić, Igor ; Wolf, Igor ; Blecich, Paolo Improvement of fuel oil spray combustion inside a 7 MW industrial furnace : A numerical study // Applied thermal engineering, 110 (2017), 795-804. doi: 10.1016/j.applthermaleng.2016.08.218

Podaci o odgovornosti

Bonefačić, Igor ; Wolf, Igor ; Blecich, Paolo

engleski

Improvement of fuel oil spray combustion inside a 7 MW industrial furnace : A numerical study

This paper presents a numerical analysis of fuel oil spray combustion inside an industrial furnace. The industrial furnace is a 7 MW cylindrical furnace which supplies heat to an oil refinery. The commercial CFD software Fluent is used for modeling transport and reaction processes in the furnace. The chosen combustion model is validated against measurement data available in the literature and good agreement is achieved. Fuel oil spray combustion is improved by varying fuel and burner parameters such as relative air-fuel ratio, fuel droplet diameter, fuel spray half-angle and burner swirl number. These parameters affect the flame shape and stability, on which depends the performance of the industrial furnace, particularly the heating output and gas species emissions. The numerical analysis revealed that complete combustion and minimum fractions of unburnt species are obtained by lean air-fuel mixtures, highly swirling flows, wide fuel spray angles and small fuel droplets. On the other side, the highest furnace heating outputs are achieved for near-stoichiometric air-fuel mixtures, narrow fuel spray angles, swirl numbers between 0.6 and 1.0 and small fuel droplets.

Numerical analysis ; Spray combustion ; Air-fuel ratio ; Swirl number ; Spray angle ; Droplet diameter

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

110

2017.

795-804

objavljeno

1359-4311

10.1016/j.applthermaleng.2016.08.218

Povezanost rada

Temeljne tehničke znanosti

Poveznice
Indeksiranost