Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Space heating and cooling energy demand in energy efficient single-family house with mechanical ventilation system (CROSBI ID 239300)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Blecich, Paolo ; Bonefačić, Igor ; Wolf, Igor Space heating and cooling energy demand in energy efficient single-family house with mechanical ventilation system // Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku, 24 (2017), Suppl. 1; 119-126. doi: 10.17559/TV-20150112153930

Podaci o odgovornosti

Blecich, Paolo ; Bonefačić, Igor ; Wolf, Igor

engleski

Space heating and cooling energy demand in energy efficient single-family house with mechanical ventilation system

This paper investigates on the space heating and cooling energy demand as well as on the thermal comfort in energy efficient detached single-family houses with mechanical ventilation heat recovery system. The necessary energy calculations are based on a test reference year with one-hour-step weather data taken for the City of Rijeka which can be seen as an average location in Croatia in terms of weather conditions. The analysis consists of the comparison of three houses with different energy performance levels: a reference single-family house, a low-energy single-family house and a passive single-family house. As expected, the space heating energy demand is lowest in the passive house and highest in the reference house. The thermal comfort is best in the passive house and worst in the reference house. It is concluded that the mechanical ventilation heat recovery system is an indispensable part of the energy system in the passive house and that it can ensure significant energy savings in the low-energy house, too.

energy efficient house ; mechanical ventilation system ; space cooling ; space heating ; thermal comfort