Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Impact of Residential Nitrogen Dioxide Exposure on Personal Exposure: An International Study (CROSBI ID 80431)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Levy, J.I. ; Spengler, J.D. ; Lee, K. ; YanagiSaša, Y. ; Bischof, W. ; Braathen, O. ; Chung, Y. ; Coward, S. ; Gutschmidt, K. ; Jin, K. et al. Impact of Residential Nitrogen Dioxide Exposure on Personal Exposure: An International Study // Journal of the Air & Waste Management Association (1995), 47 (1998), 6; 553-560

Podaci o odgovornosti

Levy, J.I. ; Spengler, J.D. ; Lee, K. ; YanagiSaša, Y. ; Bischof, W. ; Braathen, O. ; Chung, Y. ; Coward, S. ; Gutschmidt, K. ; Jin, K. ; Korenaga T. ; Ohkoda, Y. ; Meneses, F. ; Pastuszka, J. ; Patil, R.S. ; Qing, X. ; Raizenne, M. ; Salonen, R.O. ; Šega, Krešimir ; Seifert, B. ; Shah, S. ; Torres, E. ; Yoon, D. ; Zhang, X.

engleski

Impact of Residential Nitrogen Dioxide Exposure on Personal Exposure: An International Study

Nitrogen dioxide (NO2) concentrations were measured during two-day winter periods in indoor and outdoor environments, and these concentrations were compared with simultaneously measured personal exposures in 18 cities in 15 countries around the world. Information was also gathered on activity patterns and household characteristics in order to determine the influences of these factors on personal exposures. All NO2 measurements were taken using passive filter badges. Personal exposures were found to vary greatly among the array of cities, with mean concentrations ranging between 11.0 ppb and 51.5 ppb. Personal NO2 exposures were more strongly correlated with indoor concentrations (r = 0.75) than with outdoor concentrations (r = 0.57) when all countries were considered simultaneously. Use of a gas stove in the home was the dominant activity influencing NO2 concentrations, with a 67% increase in mean personal NO2 exposure and an increase in indoor-outdoor ratios from 0.7 to 1.2 for participants using gas stoves, although preliminary evidence indicates the importance of combustion space heaters as well. These associations indicate the global nature of the correlation between personal NO2 exposures and indoor NO2 sources such as gas stoves or space heaters, demonstrating that this relationship is not dependent on country-specific parameters.

Outdoor air-quality ; No2

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

47 (6)

1998.

553-560

objavljeno

1096-2247

2162-2906

Povezanost rada

Javno zdravstvo i zdravstvena zaštita

Indeksiranost