Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Influence of different glass fiber reinforcements on denture base polymer strenght (Fiber reinforcements of dental polymer) (CROSBI ID 154729)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vojvodić, Denis ; Komar , Dragutin ; Schauperl, Zdravko ; Čelebić, Asja ; Mehulić, Ketij ; Žabarović, Domagoj Influence of different glass fiber reinforcements on denture base polymer strenght (Fiber reinforcements of dental polymer) // Medicinski glasnik Ljekarske komore Zeničko-dobojskog kantona, 6 (2009), 2; 227-234

Podaci o odgovornosti

Vojvodić, Denis ; Komar , Dragutin ; Schauperl, Zdravko ; Čelebić, Asja ; Mehulić, Ketij ; Žabarović, Domagoj

engleski

Influence of different glass fiber reinforcements on denture base polymer strenght (Fiber reinforcements of dental polymer)

Aim: Assessment of flexural strength values of dental base polymers reinforced with different glass fibers ("dental" and "industrial" origin) after performed artificial ageing procedures. Methods: Three hundred specimens (dimensions 18 x 10 x 3 mm) were produced of denture base polymers reinforced with different glass fibers. The "short beam" testing method was used to determine the flexural strenght of the specimens after polymerization, immersion in water temperature 37C for 28 days, and thermo-cycling. Results: Flexural strength of the polymer specimens reinforced with glass fibers demonstrated rise of flexural strength values (103.10 - 163.88 MPa), no matter which type ("dental" or "industrial") fibers was used. Microscopic examination revealed partial bonding between the glass fibers and the polymer material. Conclusion: Both of the investigated glass fibers had similar strengthening effect, but due to the better investment/benefit ratio "industrial" glass fibers could be recommended for dental laboratory use. Prolonged polymerization of denture base materials should be proposed because it had direct impact on the improvement of flexural strength values.

dental materials ; polymers ; glass fibers ; dental prothesis ; mechanical phenomena

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (2)

2009.

227-234

objavljeno

1840-0132

Povezanost rada

Dentalna medicina, Strojarstvo

Indeksiranost