Effects of polymerisation unit on the flexural strength of Glass carbomer (CROSBI ID 557221)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Goršeta, Kristina ; Negovetić Vranić, Dubravka ; Glavina, Domagoj ; Škrinjarić, Ilija Effects of polymerisation unit on the flexural strength of Glass carbomer // International journal of paediatric dentistry. 2009. str. 75-x

Podaci o odgovornosti

Goršeta, Kristina ; Negovetić Vranić, Dubravka ; Glavina, Domagoj ; Škrinjarić, Ilija

engleski

Effects of polymerisation unit on the flexural strength of Glass carbomer

Introduction: The aim of this study was to measure the flexural strength (FS) of new nano-ionomer cement and to determine if strength can be related to polymerisation unit and applied light intensity. Materials and methods: The FS of commercial glass ionomer (Fuji IX GP Fast, GC) and new nano-ionomer cement (Glass Carbomer)were measured using a method based on ISO9917-2:1998. Specimens (n = 10 per group) were prepared in SS split moulds (2 • 2 • 25 mm), compressed and light-cured according to manufacturers’ instructions, stored at 37_C (100% RH) for 24 h. Light curing was carried out immediately after mixing using Bluephase G2 (IvoclarVivadent), Elipar_ FreeLight 2 and Elipar_TriLight (3M ESPE). Each specimen was tested using an Universal testing machine at 1 mm/min crosshead speed and loaded to fracture using a 3-point bending test (l = 20 mm), with 1 kN load cell. Data were analysed by ANOVA and Bonferroni post hoc test P < 0.05. Results: FS of Glass Carbomer (122.29 ± 9.9 MPa) was significantly higher than value for highly viscous glass ionomer Fuji IX (57.85 ± 7.54 MPa) (P < 0.001). There were no statistically significant differences in FS of GlassCarbomer samples cured by means of different light sources. FS of Fuji IX GP fast cured with EliparFreeLight (98.87 ± 20 MPa) showed significantly higher results than samples cured with halogen lamp (31.27 ± 7.49 MPa)(P < 0.001). Conclusion: The nano-ionomer cement Glass Carbomer shows higher flexural strength than highly viscous glass ionomer cement cured by different types of curing light. Different types of curing light (halogen lamp and LED lamp) significantly influence flexural strength of glass ionomer cement.

flexural strength; nano-ionomer cement

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

75-x.

2009.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

International journal of paediatric dentistry

Wiley-Blackwell

0960-7439

Podaci o skupu

22nd Congress of the International Association of Paediatric Dentistry

poster

17.06.2009-20.06.2009

München, Njemačka

Povezanost rada

Dentalna medicina

Indeksiranost