Maintaining desired level of relative humidity throughout a fuel cell with spatially variable heat removal rates (CROSBI ID 173747)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Tolj, Ivan ; Bezmalinović, Dario ; Barbir, Frano
engleski
Maintaining desired level of relative humidity throughout a fuel cell with spatially variable heat removal rates
A concept of using the product water to internally humidify the air stream in a PEM fuel cell without external humidification is investigated by a simple, pseudo 2-D model along a single channel. This model takes into account the mass and energy balance, water and heat generation rates, heat removal, and water transport through the membrane. The model and thus the concept were confirmed experimentally using a 5-segment fuel cell. The temperature of each segment could be individually controlled, and the temperature and humidity of air could be measured between each segment. A temperature profile has been established, by applying spatially variable heat removal rates along the cathode channel, that results in relative humidity being close to 100% throughout the cell without any external humidification. The concept may be applied to a fuel cell stack resulting in simplification of the suporting system by avoiding external humidification.
PEM fuel cell; Water management; Relative humidity; Segmented model; Humid air Mollier diagram
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
36 (20)
2011.
13105-13113
objavljeno
0360-3199
10.1016/j.ijhydene.2011.07.078