Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Application of the Ultrasonic Method in Evaluation of Properties of Stabilized Mixes (CROSBI ID 174589)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Dimter, Sanja ; Rukavina, Tatjana ; Barišić, Ivana Application of the Ultrasonic Method in Evaluation of Properties of Stabilized Mixes // Baltic journal of road and bridge engineering, VI (2011), 3; 177-184. doi: 10.3846/bjrbe.2011.23

Podaci o odgovornosti

Dimter, Sanja ; Rukavina, Tatjana ; Barišić, Ivana

engleski

Application of the Ultrasonic Method in Evaluation of Properties of Stabilized Mixes

Application of nondestructive methods in assessing the properties of materials and mixes is very popular because of their simplicity and noninvasive nature. The ultrasonic method is, as one of nondestructive methods, used for more than 60 years in determining the properties of concrete mixes. However, only recently it has been applied application in studies of the stabilization mixes intended for road construction. The ultrasonic method is based on measurement of the travel time of longitudinal ultrasonic waves through the sample. In this paper, the investigation of stabilized mixes containing sand from river Drava stabilized with cement and fly ash are presented. The aim of the research was to determine the impact of changes in the composition of mixes and in the regime of care on the density, compressive strength and ultrasonic velocity. An additional goal was to analyze the relationship between the investigated properties of mixes and the ultrasonic velocity. The compressive strength of the stabilized mixture is determined by the destructive method according to Croatian Standards HRN.U.B1.030 Unconfined Compressive Strength as the average stress in a sample during uniaxial compression testing at the ultimate force. Testing of density and compressive strength of mixes and determination of the ultrasonic speed has been performed after 7, 28 and 90 days of curing at four different temperatures: 5 °C, 15 °C, 25 °C and 35 °C. The obtained results indicated the direct influence of fly ash quantity on the observed properties. Increase in the amount of fly ash caused a decrease in the mixture compressive strength, its density and ultrasonic velocity. A significant influence of treatment temperature on the compressive strength, density and ultrasonic velocity was also observed. Finally, correlation between density and ultrasonic velocity, as well as compressive strength and ultrasonic velocity was established. Exponential relationship between the compressive strength of stabilized mixes and ultrasonic velocity proved to be very strong, and similar to those obtained in previous studies by other researchers. Test results showed that the ultrasonic method can be useful in assessing properties of stabilized mixes.

properties; fly ash stabilized mixes; density; compressive strength; ultrasonic pulse velocity; regression models

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

VI (3)

2011.

177-184

objavljeno

1822-427X

10.3846/bjrbe.2011.23

Povezanost rada

Građevinarstvo

Poveznice
Indeksiranost