Testing of Measuring Frequency of Electro-Optical Distance Meters (CROSBI ID 587464)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Barković, Đuro ; Zrinjski, Mladen ; Peša, Martina Testing of Measuring Frequency of Electro-Optical Distance Meters // Conference Proceedings, Volume II - 12th International Multidisciplinary Scientific GeoConference SGEM 2012 / International Multidisciplinary Scientific GeoConference SGEM (ur.). Sofija: International Multidisciplinary Scientific GeoConferences (SGEM), 2012. str. 805-812

Podaci o odgovornosti

Barković, Đuro ; Zrinjski, Mladen ; Peša, Martina

engleski

Testing of Measuring Frequency of Electro-Optical Distance Meters

The multiplication constant of electro-optical distance meters is changed as a result of quartz crystals aging in the distance meter oscillator. Other parts are also aging, the misalignment of instruments occurs during the transportation, along with the deformation caused by the temperature changes. It is therefore necessary to measure the measuring frequency in distance meters regularly. The measuring frequency of distance meters is tested in the laboratory conditions by means of frequency counter that needs to be calibrated previously. A new method of automated frequency counter calibrations by means of GPS signal has been developed in the Laboratory for Measurements and Measuring Technique at the Faculty of Geodesy, University of Zagreb. The paper describes the system for automated measurement of frequency in the electro-optical distance meters Leica TC1800 and Leica TCA2003. The measurements were performed in the Laboratory for Measurements and Measuring Technique at the Faculty of Geodesy, University of Zagreb at three temperatures, approximately: 13 °C, 20 °C and 31 °C. There is also the manner of recording the measuring data presented that is performed by means of the software Agilent IntuiLink Counter version 1.0. At the end, the data obtained from testing of the measuring frequency in the electro-optical distance meters TC1800 and Leica TCA2003 are presented graphically.

measuring frequency; electro-optical distance meter; air temperature; multiplication constant

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

805-812.

2012.

objavljeno

Podaci o matičnoj publikaciji

Conference Proceedings, Volume II - 12th International Multidisciplinary Scientific GeoConference SGEM 2012

International Multidisciplinary Scientific GeoConference SGEM

Sofija: International Multidisciplinary Scientific GeoConferences (SGEM)

1314-2704

Podaci o skupu

12th International Multidisciplinary Scientific GeoConference SGEM 2012

ostalo

17.06.2012-23.06.2012

Albena, Bugarska

Povezanost rada

Geodezija