Evaluating EQA results in general medical biochemistry - standardization of creatinine measurements (CROSBI ID 590959)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Perkov, S. Evaluating EQA results in general medical biochemistry - standardization of creatinine measurements // Biochemia Medica 2012 ; 22(3):267-402 ; A17-A204 / Šimundić, AM (ur.). Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM), 2012. str. A27-A27

Podaci o odgovornosti

Perkov, S.

engleski

Evaluating EQA results in general medical biochemistry - standardization of creatinine measurements

The standardization of creatinine measurement is critical to promote early detection and management of chronic kidney disease and is mandatory before the routine implementation of the estimated glomerular filtration rate in clinical practice. Actual results for serum creatinine measurement in Croatia were compared with the current recommendations based on creatinine measurements traceable to isotope dilution mass spectrometry (IDMS) reference method within the national External Quality Assessment (EQA) Scheme conducted through Croatian Centre for Quality Assesment in Laboratory Medicine (CROQALM). The results of the cycle 2/2011, 3/2011 and 1/2012 from 187 medical biochemistry laboratories were evaluated. The uncompensated kinetic Jaffe method traceable to National Institute of Standards and Technology (NIST)Standard Reference Material (SRM) 909b level 2 is most widely used in medical biochemistry laboratories (80%, 73% and 68% of participants in the survey 2/2011, 3/2011 and 1(2012, respectively=. Only 17%, 24% and 29% laboratories in the survey 2/2011, 3/2011 and 1/2012 used standardized creatinine methods traceable to the IDMS method and SRM 967. The interlaboratory SD for compensated kinetic Jaffe method group, traceable to the IDMS method and SRM 967 was very high: 12, 1 umol/L at a creatinine concentration of 98, 8 umol/L (12%), 19, 3 umol/L at a creatinine concentration of 204 umol/L (9%) and 28, 6 umol/L at a creatinine concentration of 495, 8 umol/L (6%). One of the main goals of the Croatian EQA program in 2012 is to promote laboratories to implement standardized method and reduce the inter-laboratory variability which affects the total error for creatinine measurement.

EQA; standardization; creatinine measurements

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

A27-A27.

2012.

objavljeno

Podaci o matičnoj publikaciji

Biochemia Medica 2012 ; 22(3):267-402 ; A17-A204

Šimundić, AM

Zagreb: Hrvatsko društvo za medicinsku biokemiju i laboratorijsku medicinu (HDMBLM)

1330-60962

Podaci o skupu

2nd European Joint Congress of European Federation of Clinical Chemistry and Laboratory Medicine (EFCC) and European Union of Medical Specialists (UEMS)/7th Congress of Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM)

predavanje

10.10.2012-13.10.2012

Dubrovnik, Hrvatska

Povezanost rada

Farmacija