Diagnostics of stable wire corona generated by small Z-pinch (CROSBI ID 479134)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Kubeš, Pavel ; Kravarik, Joseph ; Aschke, Lutz ; Andreić ; , Željko ; Kunze, Hans-Joachim
engleski
Diagnostics of stable wire corona generated by small Z-pinch
In this paper, the results of a XUV PIN diode and spectrometer diagnostics of the non-thermal XUV emission from a carbon wire corona are presented at the 200 J energy Z-pinch discharge, in the case when the central axis rest of the wire remains in solid state. 60% of the total radiated energy of 160 mJ is emitted in the window of 17-35 nm. The XUV spectrometer temporal resolving diagnostics enabled to determine: the presence of OVI, OV, OIV and CIV ions, electron temperature 10 eV from OVI ions and no-Boltzmann intensities of OV and OIV lines.
52.55.Ez Z-Pinch; theta pinch; plasma focus and other pinch devices
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
979-984-x.
1999.
objavljeno
Podaci o matičnoj publikaciji
Podaci o skupu
14th International Symposium on Plasma Chemistry
predavanje
02.08.1999-06.08.1999
Prag, Češka Republika