Use of portable X-ray fluorescence instrument for bulk alloy analysis on low corroded indoor bronzes (CROSBI ID 195577)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šatović, Domagoj ; Desnica, Vladan ; Fazinić, Stjepko Use of portable X-ray fluorescence instrument for bulk alloy analysis on low corroded indoor bronzes // Spectrochimica acta. Part B, Atomic spectroscopy, 89 (2013), 7-13. doi: 10.1016/j.sab.2013.08.007

Podaci o odgovornosti

Šatović, Domagoj ; Desnica, Vladan ; Fazinić, Stjepko

engleski

Use of portable X-ray fluorescence instrument for bulk alloy analysis on low corroded indoor bronzes

One of the most often used non-destructive methods for elemental analysis when performing field measurements on bronze sculptures is X-ray fluorescence (XRF) analysis based on portable instrumentation. However, when performing routine in-situ XRF analysis on corroded objects obtained results are sometimes considerably influenced by the corrosion surface products. In thiswork the suitability of portable XRF for bulk analysis of lowcorroded bronzes, whichwere initially precisely characterized using sophisticated and reliable laboratory methods, was investigated and some improvements in measuring technique and data processingwere given. Artificially corroded bronze sampleswere analyzed by a portable XRF instrument using the same methodology and procedures as when performing in-situ analysis on real objects. The samples were first investigated using sophisticated complementary laboratory techniques: Scanning Electron Microscopy, Proton-Induced X-ray Emission Spectroscopy and Rutherford Backscattering Spectrometry, in order to gain precise information on the formation of the corrosion product layers and indepth elemental profile of corrosion layers for different aging parameters. It has been shown that for corrosion layers of up to ca. 25 μm a portable XRF can yield very accurate quantification results.

X-ray fluorescence analysis ; non-destructive analysis ; corrosion ; bronze ; archaeometry

Glavni autor : Šatović Domagoj

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

89

2013.

7-13

objavljeno

0584-8547

1873-3565

10.1016/j.sab.2013.08.007

Povezanost rada

Fizika, Kemijsko inženjerstvo, Temeljne tehničke znanosti, Znanost o umjetnosti

Poveznice
Indeksiranost