Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Preparation and application of sulfaguanidine-imprinted polymer on solid-phase extraction of pharmaceuticals from water (CROSBI ID 208398)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Mutavdžić Pavlović, Dragana ; Nikšić, Korana ; Livazović, Sara ; Brnardić, Ivan ; Anžlovar, Alojz Preparation and application of sulfaguanidine-imprinted polymer on solid-phase extraction of pharmaceuticals from water // Talanta, 131 (2015), 99-107. doi: 10.1016/j.talanta.2014.06.065

Podaci o odgovornosti

Mutavdžić Pavlović, Dragana ; Nikšić, Korana ; Livazović, Sara ; Brnardić, Ivan ; Anžlovar, Alojz

engleski

Preparation and application of sulfaguanidine-imprinted polymer on solid-phase extraction of pharmaceuticals from water

The molecularly imprinted polymers (MIPs) with sulfaguanidine as a template, methacrylic acid, 4- vinylpyridine, and 2-hydroxyethyl methacrylate as a functional monomers, ethylene glycol dimethacrylate as a cross-linker and 2, 2´- azobis-isobutyronitrile as an initiator have been prepared through the cross-link reaction of polymerization. Solid-phase extraction (SPE) procedure for the extraction of sulfaguanidine from water samples using the prepared MIPs and non-imprinted (NIPs) was evaluated. The best MIP in combination with commercial sorbents was applied for simultaneous extraction of eight pharmaceuticals. New SPE cartridges were prepared by combination of optimal produced MIP and Oasis HLB in 6 mL of polypropilene SPE reservoir. Developed method which includes new SPE cartridge (MIPMAA-Oasis HLB, 400 mg/ 6 mL) and thin-layer chromatography was validated. The method provides a linear response over the concentration range of 0.5-150 μg/L, depending on the pharmaceutical with the correlation coefficients > 0.9843 in all cases except for norfloxacin (0.9770) and penicillin G procaine (0.9801). Also, the method has revealed low limits of detection (0.25–20 μg/L), good precision (intra and inter-day), a relative standard deviation below 15% and recoveries above 95% for all eight pharmaceuticals. The developed method by using newly prepared SPE cartridge has been successfully applied to the analysis of production wastewater samples from pharmaceutical industry.

sulfaguanidine ; molecularly imprinted polymers ; pharmaceuticals ; production wastewater

Glavni autori: Dragana Mutavdžić Pavlović

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

131

2015.

99-107

objavljeno

0039-9140

1873-3573

10.1016/j.talanta.2014.06.065

Povezanost rada

Kemija, Kemijsko inženjerstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost