Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Voltammetric determination of ropinirole in the presence of levodopa at the surface of a carbon nanotubes based electrochemical sensor in pharmaceuticals and human serum (CROSBI ID 209981)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sadiković, Mirela ; Nigović, Biljana ; Jurić, Sandra ; Mornar, Ana Voltammetric determination of ropinirole in the presence of levodopa at the surface of a carbon nanotubes based electrochemical sensor in pharmaceuticals and human serum // Journal of electroanalytical chemistry (1992), 733 (2014), 60-68. doi: 10.1016/j.jelechem.2014.09.020

Podaci o odgovornosti

Sadiković, Mirela ; Nigović, Biljana ; Jurić, Sandra ; Mornar, Ana

engleski

Voltammetric determination of ropinirole in the presence of levodopa at the surface of a carbon nanotubes based electrochemical sensor in pharmaceuticals and human serum

A nanostructured electrochemical sensor was developed to establish an innovative way to measure ropinirole and levodopa in real pharmaceutical and biological samples, which offers a high selectivity derived from the stable carbon nanotubes-Nafion polymer film. The surface morphology of the modified electrodes was characterized by scanning electron microscopy. The effect of surface modifications, supporting electrolyte, amount of carbon nanotubes suspension, accumulation time and potential were investigated. A sensitive electroanalytical methodology for the simultaneous determination of both drugs co-administrated in advanced Parkinson’s disease patients using adsorptive stripping square-wave voltammetry is presented. Under the optimized conditions, ropinirole and levodopa gave a linear response in the range 1 × 10-7 - 1 × 10-5 M and 2.5 × 10-7 - 1 × 10-5 M with detection limits 1.6 × 10-8 M and 5.2 × 10-8 M, respectively. The method was successfully utilised for their quantification in human serum samples and good recoveries were obtained without interference from endogenous dopamine, uric and ascorbic acid. In addition, the proposed sensor was successfully applied in the independent determination of ropinirole and levodopa content in pharmaceutical formulations, whose accuracy was attested by good agreement of the results with those, obtained using high performance liquid chromatography. The proposed sensor is characterized by high sensitivity and reproducibility, simple fabrication procedure, easy handling, resistance against surface fouling and low cost.

Ropinirole ; Levodopa ; Carbon nanotubes ; Electrochemical sensor ; Stripping analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

733

2014.

60-68

objavljeno

1572-6657

10.1016/j.jelechem.2014.09.020

Povezanost rada

Farmacija

Poveznice
Indeksiranost