Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Quality specifications based on biological variation – where are we? (CROSBI ID 619383)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Ćelap, Ivana ; Juriček, Jasna ; Perović, Antonija ; Puc, Nikolina ; Šupak Smolčić, Vesna ; Vukasović, Ines Quality specifications based on biological variation – where are we? // Biochimica Clinica / Panteghini, Mauro (ur.). Brescia: Società Italiana di Biochimica Clinica (SIBioC), 2013. str. S417-S417

Podaci o odgovornosti

Ćelap, Ivana ; Juriček, Jasna ; Perović, Antonija ; Puc, Nikolina ; Šupak Smolčić, Vesna ; Vukasović, Ines

engleski

Quality specifications based on biological variation – where are we?

Consensus recommendations on the quality targets in laboratory medicine supports hierarchy quality model. In this concept, a model higher in the hierarchy should be preferred over lower one. The analytical performance in the majority of laboratories in our country is evaluated according to manufacturer recommendations, which is the lowest model in the hierarchy. Thus, we aimed to compare analytical coefficients of variation (CVa) against criteria for imprecision based on biological variation from five different laboratories. Imprecision of 17 biochemistry parameters (amylase, AST, ALT, bilirubin – total and conjugated, Ca, Cl, CK, CK-MB, creatinine, CRP, glucose, K, LD, Na, urea and total protein) was monitored by analyzing two levels of commercial quality control material, three times per day, over one year. CVa was monitored on four different platforms (AU2700, AU480, Architect ci 4100 and Cobas c501). Obtained CVa for each platform was evaluated against criteria for imprecision based on biological variation. Comparison against biological variation was as follows: all monitored parameters met the optimum quality specifications only on AU480, while CVa monitored on the rest of the platforms (AU2700, Architect ci 4100 and Cobas c501) did not meet quality specifications based on biological variation for four parameters (sodium, chloride, calcium and total protein). According to our results sodium, chloride, calcium and total protein did not meet quality requirements on three different platforms. One of the possible reasons is low within-subject biological variation which is difficult to achieve with available analytical methods.

biological variation ; quality specifications

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

S417-S417.

2013.

objavljeno

Podaci o matičnoj publikaciji

Biochimica Clinica

Panteghini, Mauro

Brescia: Società Italiana di Biochimica Clinica (SIBioC)

0393-9564

Podaci o skupu

20th IFCC EFCC European Congress of Clinical Chemistry and Laboratory Medicine

poster

19.05.2013-23.05.2013

Milano, Italija

Povezanost rada

Farmacija

Indeksiranost