Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Analysis of Translucency Parameter of Glass- Ceramics Fabricated by Different Techniques (CROSBI ID 217211)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ledić, Karla ; Majnarić, Igor ; Milardović Ortolan, Slađana ; Špalj, Stjepan ; Štefančić, Sanja ; Mehulić, Ketij Analysis of Translucency Parameter of Glass- Ceramics Fabricated by Different Techniques // Acta stomatologica Croatica, 49 (2015), 1; 27-35. doi: 10.15644/asc49/1/4

Podaci o odgovornosti

Ledić, Karla ; Majnarić, Igor ; Milardović Ortolan, Slađana ; Špalj, Stjepan ; Štefančić, Sanja ; Mehulić, Ketij

hrvatski

Analysis of Translucency Parameter of Glass- Ceramics Fabricated by Different Techniques

The purpose of the study was to analyse translucency of glass-ceramics fabricated by different techniques and investigate the effect of the corrosive medium on the translucency. Materials and methods: Three specimens of each type of IPS e.max ceramics (Ivoclar Vivadent, Schaan, Liechtenstein) were made in three colours (A2, C2 and B3) by three fabrication techniques (layering – e.max Ceram Dentin ; heat-pressing – e.max Press ; CAD/CAM – e.max CAD). Specimens were made in the form of plates (10 mm x 12 mm x 0.8 mm).CIE L*a*b* values were measured by a spectrophotometer (X-Rite DTP 20 Pulse, Neu Isenburg, Germany) before and after exposure to 4% acetic acid at 80 °C for 16 hours (ISO 6872) to calculate translucency parameter (TP values). Statistical data were analysed using the IBM SPSS 22 software. Results: IPS e.max Ceram Dentin had significantly the lowest TP values, and IPS e.max Press the highest TP values of all colours (A2, C2, B3), both prior and after exposure to acid (p<0.001). The difference in TP values among colours was evident in the IPS e.max Ceram Dentin material, both before and after exposure to acid with a great effect size (p<0.001 ; η2 = 0.702 and 0.741), and in the IPS e.max Press material (p<0.001, effect size 0.547 and 0.576). CAD/CAD specimens showed uniform TP values between three colours. Further, exposure to a corrosive medium did not result in a statistically significant change of TP values in any of the materials tested. Conclusions: Different types of glass- ceramics showed significant difference in TP values both with respect to the fabrication technique and colour. Exposure to a corrosive medium did not result in a statistically significant change of TP values.

glass ceramics ; spectrophotometry ; optical phenomena ; corrosion ; acetic acid ; translucency

nije evidentirano

engleski

Analysis of Translucency Parameter of Glass- Ceramics Fabricated by Different Techniques

The purpose of the study was to analyse translucency of glass-ceramics fabricated by different techniques and investigate the effect of the corrosive medium on the translucency. Materials and methods: Three specimens of each type of IPS e.max ceramics (Ivoclar Vivadent, Schaan, Liechtenstein) were made in three colours (A2, C2 and B3) by three fabrication techniques (layering – e.max Ceram Dentin ; heat-pressing – e.max Press ; CAD/CAM – e.max CAD). Specimens were made in the form of plates (10 mm x 12 mm x 0.8 mm).CIE L*a*b* values were measured by a spectrophotometer (X-Rite DTP 20 Pulse, Neu Isenburg, Germany) before and after exposure to 4% acetic acid at 80 °C for 16 hours (ISO 6872) to calculate translucency parameter (TP values). Statistical data were analysed using the IBM SPSS 22 software. Results: IPS e.max Ceram Dentin had significantly the lowest TP values, and IPS e.max Press the highest TP values of all colours (A2, C2, B3), both prior and after exposure to acid (p<0.001). The difference in TP values among colours was evident in the IPS e.max Ceram Dentin material, both before and after exposure to acid with a great effect size (p<0.001 ; η2 = 0.702 and 0.741), and in the IPS e.max Press material (p<0.001, effect size 0.547 and 0.576). CAD/CAD specimens showed uniform TP values between three colours. Further, exposure to a corrosive medium did not result in a statistically significant change of TP values in any of the materials tested. Conclusions: Different types of glass- ceramics showed significant difference in TP values both with respect to the fabrication technique and colour. Exposure to a corrosive medium did not result in a statistically significant change of TP values.

glass ceramics ; spectrophotometry ; optical phenomena ; corrosion ; acetic acid ; translucency

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

49 (1)

2015.

27-35

objavljeno

0001-7019

1846-0410

10.15644/asc49/1/4

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost