Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Dynamic Tests of a Large-Scale Three-Story RC Structure with Masonry Infill Walls (CROSBI ID 251753)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Guljaš, Ivica ; Penava, Davorin ; Laughery, Lucas ; Pujol, Santiago Dynamic Tests of a Large-Scale Three-Story RC Structure with Masonry Infill Walls // Journal of earthquake engineering, 24 (2020), 11; 1675-1703. doi: 10.1080/13632469.2018.1475313

Podaci o odgovornosti

Guljaš, Ivica ; Penava, Davorin ; Laughery, Lucas ; Pujol, Santiago

engleski

Dynamic Tests of a Large-Scale Three-Story RC Structure with Masonry Infill Walls

RC Buildings with masonry infill walls are common throughout the world. There is uncertainty about the effect of the infill walls on the response of the building to earthquake demands. To shed light on this issue, a three-story, scaled reinforced concrete frame with masonry infill walls was subjected to two sequences of base motions in two series of tests. In Series 1, hollow masonry units were used. After completion of this series, the structure was repaired by replacing hollow masonry units with new solid units. Reinforced concrete confining elements were also added along the vertical edges of window and door openings in the first and second stories. The repaired structure was then tested with the same sequence of base motions in Series 2. On average, drift demands were 30% smaller in Series 2 and were nearly half what the drift demands were estimated to be for the bare RC frame alone. These results support the hypothesis that masonry infill panels can be used to control drift in low-rise structures, provided they do not cause column failures and provided they are restrained from out-of-plane collapse. Projections made based on the test results also support the idea that a Wall Index (ratio of masonry wall density to ten times the number of stories) exceeding 0.2% leads to acceptable earthquake response in low-rise buildings.

Dynamic Tests ; Large-Scale ; Three-Story RC Structure ; Masonry Infill Walls ; Earthquake Action ; Wall Index

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

24 (11)

2020.

1675-1703

objavljeno

1363-2469

10.1080/13632469.2018.1475313

Povezanost rada

Građevinarstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost