Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Turbogenerator steam turbine variation in developed power: analysis of exergy efficiency and exergy destruction change (CROSBI ID 252818)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Mrzljak, Vedran ; Senčić, Tomislav ; Žarković, Božica Turbogenerator steam turbine variation in developed power: analysis of exergy efficiency and exergy destruction change // Modelling and simulation in engineering, 2018 (2018), 2945325, 12. doi: 10.1155/2018/2945325

Podaci o odgovornosti

Mrzljak, Vedran ; Senčić, Tomislav ; Žarković, Božica

engleski

Turbogenerator steam turbine variation in developed power: analysis of exergy efficiency and exergy destruction change

Developed power variation of turbogenerator (TG) steam turbine, which operates at the conventional LNG carrier, allows insight into the change in turbine exergy efficiency and exergy destruction during the increase in turbine power. Measurements of required operating parameters were performed in eight different TG steam turbine operating points during exploitation. Turbine exergy efficiency increases from turbine power of 500 kW up to 2700 kW, and maximum exergy efficiency was obtained at 70.13% of maximum turbine developed power (at 2700 kW) in each operating point. From turbine developed power of 2700 kW until the maximum power of 3850 kW, exergy efficiency decreases. Obtained change in TG turbine exergy efficiency is caused by an uneven intensity of increase in turbine developed power and steam mass flow through the turbine. TG steam turbine exergy destruction change is directly proportional to turbine load and to steam mass flow through the turbine—higher steam mass flow results in a higher turbine load which leads to the higher exergy destruction and vice versa. The higher share of turbine developed power and the lower share of turbine exergy destruction in the TG turbine exergy power inlet lead to higher turbine exergy efficiencies. At each observed operating point, turbine exergy efficiency in exploitation is lower when compared to the maximum obtained one for 8.39% to 12.03%.

low power steam turbine ; exergy efficiency ; exergy destruction ; developed power variation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

2018

2018.

2945325

12

objavljeno

1687-5591

1687-5605

10.1155/2018/2945325

Povezanost rada

Strojarstvo

Poveznice
Indeksiranost