Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Ascorbic acid – black hole of urine chemistry screening (CROSBI ID 253901)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Unic, Adriana ; Nikolac Gabaj, Nora ; Miler, Marijana ; Culej, Jelena ; Lisac, Adriana ; Horvat, Anita ; Vrkic, Nada Ascorbic acid – black hole of urine chemistry screening // Journal of clinical laboratory analysis, 32 (2018), 5; e22390, 8. doi: 10.1002/jcla.22390

Podaci o odgovornosti

Unic, Adriana ; Nikolac Gabaj, Nora ; Miler, Marijana ; Culej, Jelena ; Lisac, Adriana ; Horvat, Anita ; Vrkic, Nada

engleski

Ascorbic acid – black hole of urine chemistry screening

Study was performed in order: (i) to assess the comparability of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein ; (ii) to assess accuracy of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein ; and (iii) to evaluate interference of ascorbic acid on the glucose, bilirubin, hemoglobin, and nitrite determination using 2 different dipsticks: iChem Velocity, Iris Diagnostics and Combur-10M, Roche Diagnostics. Random urine specimens were included in the study. Comparability, accuracy, and ascorbic acid interference testing were performed. Obtained results have shown almost perfect agreement for all parameters between 2 dipsticks in samples with negative ascorbic acid. Agreement in samples with positive ascorbic acid was not acceptable for bilirubin, protein, nitrite, and hemoglobin. Accuracy was not acceptable for hemoglobin and leukocyte esterase on both dipsticks. Ascorbic acid interference examination has shown that intensity of interference differs between dipsticks. Ascorbic acid interferes with glucose, hemoglobin, nitrite, and bilirubin at different concentrations causing false-negative results. Obtained results indicate that it is necessary to determine diagnostic accuracy of used dipstick in order to define purpose of urinalysis. It is very important to choose dipstick with ascorbic acid indicator and to examine ascorbic acid impact on dipstick analytes independently of manufacturer claims.

Urinalysis ; Diagnostic accuracy ; Interference ; Ascorbic acid

Rad/časoois indeksiran je i u: Natural Science Collection ; Nutrition Abstracts & Reviews Series A ; ProQuest Central ; Public Health Database ; PubMed Dietary Supplement Subset ; SciTech Premium Collection.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

32 (5)

2018.

e22390

8

objavljeno

0887-8013

1098-2825

10.1002/jcla.22390

Povezanost rada

Kliničke medicinske znanosti, Farmacija

Poveznice
Indeksiranost