Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Shear Bond Strength of Orthodontic Brackets Luted with RMGIC After Er:YAG Laser Etching with Two Pulse Modes Using a Digitally Controlled “X-Runner” Handpiece (CROSBI ID 257523)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Latić Hodžić, Leila ; Iionescu, Andrei C ; Brambilla, Eugenio ; Basso, Matteo ; Gabrić, Dragana ; Meštrović, Senka Shear Bond Strength of Orthodontic Brackets Luted with RMGIC After Er:YAG Laser Etching with Two Pulse Modes Using a Digitally Controlled “X-Runner” Handpiece // Photomedicine and laser surgery, 36 (2018), 11; 608-613. doi: 10.1089/pho.2018.4461

Podaci o odgovornosti

Latić Hodžić, Leila ; Iionescu, Andrei C ; Brambilla, Eugenio ; Basso, Matteo ; Gabrić, Dragana ; Meštrović, Senka

engleski

Shear Bond Strength of Orthodontic Brackets Luted with RMGIC After Er:YAG Laser Etching with Two Pulse Modes Using a Digitally Controlled “X-Runner” Handpiece

Objective: To compare the shear bond strength (SBS) values of orthodontic brackets luted using a resin-modified glass ionomer cement (RMGIC) on enamel surfaces etched using either an Er:YAG laser in two different working modes, or a conventional etching protocol, including phosphoric acid. Materials and methods: Sixty healthy human premolars were randomly allocated to three experimental groups (n = 20) and etched with: Group 1: Er:YAG laser in super-short pulse (SSP) mode (100 mJ, 20 Hz, 2 W) ; Group 2: Er:YAG laser in quantum square pulse mode (120 mJ, 10 Hz, 1.2 W) using a digitally controlled handpiece (“X-Runner”) ; Group 3 (control): 5.25% sodium hypochlorite pretreatment, then 37% phosphoric acid for 15 sec. Stainless steel brackets were bonded using light-curing RMGIC for orthodontic bonding. After term cycling (1800 cycles), SBS testing was performed using a universal testing machine. After debonding, both enamel and bracket surfaces were examined to determine the amount of RMGIC still present on the surfaces. Results: Group 3 surfaces gave the lowest mean SBS (10.6104 ± 2.66196 MPa), whereas Group 1 provided the highest 1 (13.1795 ± 3.37904 MPa), which was significantly different from the control (Group 3, p = 0.0226). Group 2 provided intermediate values (11.8486 ± 0.59832 MPa) nonsignificantly different from the control or from SSP (p = 0.4215 and p = 0.3082, respectively). Conclusions: Er:YAG laser treatment in SSP mode of enamel surfaces for orthodontic bonding provided higher SBS and a shear behavior of the luting material similar to the conventional acid-etching procedures, making it a viable alternative to acid etching.

Er: YAG laser ; enamel surface conditioning ; orthodontic bonding ; SEM analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

36 (11)

2018.

608-613

objavljeno

1549-5418

1557-8550

10.1089/pho.2018.4461

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost