Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Influence of Cutting Fluids on the Corrosion Resistance of X20Cr13 Martensitic Stainless Steel (CROSBI ID 258783)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kostadin, Tihana ; Cukor, Goran ; Jurković, Zoran Influence of Cutting Fluids on the Corrosion Resistance of X20Cr13 Martensitic Stainless Steel // International journal of electrochemical science, 13 (2018), 12; 11986-11999. doi: 10.20964/2018.12.81

Podaci o odgovornosti

Kostadin, Tihana ; Cukor, Goran ; Jurković, Zoran

engleski

Influence of Cutting Fluids on the Corrosion Resistance of X20Cr13 Martensitic Stainless Steel

Martensitic stainless steels are difficult-to-cut materials, so the utilization of the cutting fluids with high flow rates is considered necessary in their machining. However, flood cooling method represents a high risk to human health and environment and is also a great economic burden. A chilled jet of compressed air is one of the possible alternatives to conventional liquid coolants. As corrosion can occur even in dry machining, the aim of this paper was to investigate the feasibility of replacing conventional emulsion coolant with the chilled air out of Ranque-Hilsch counter-flow vortex tube. An important outcome of corrosion testing showed a beneficial effect of the chilled air-cooling method on the corrosion resistance since it is on increase over a prolonged time. As expected, the feed rate f was confirmed to be the most important factor affecting the Ra, but the most interesting finding was that about non-significant influence of the cooling method on reducing the Ra and consequently on increasing the corrosion resistance of machined surface. Therefore, the chilled air-cooling by a vortex tube can be successfully applied to turning of steel X20Cr13, thereby eliminating the ecological load caused by the application of conventional liquid coolant.

martensitic stainless steel ; corrosion resistance ; cooling ; electrochemical and gravimetric measurements.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

13 (12)

2018.

11986-11999

objavljeno

1452-3981

10.20964/2018.12.81

Povezanost rada

Kemijsko inženjerstvo, Strojarstvo

Poveznice
Indeksiranost