Impact of the Spread-Spectrum Technique on the Higher-Order Harmonics and Radiated Emissions of a Synchronous Buck Converter
Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Impact of the Spread-Spectrum Technique on the Higher-Order Harmonics and Radiated Emissions of a Synchronous Buck Converter (CROSBI ID 680493)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Raul Blečić ; Josip Bačmaga ; Adrijan Barić ; Fabio Pareschi ; Riccardo Rovatti ; Gianluca Setti Impact of the Spread-Spectrum Technique on the Higher-Order Harmonics and Radiated Emissions of a Synchronous Buck Converter // Proceedings of New Generation of Circuits and Systems (NGCAS). 2018. str. 13-16. doi: 10.1109/NGCAS.2018.8572290

Podaci o odgovornosti

Raul Blečić ; Josip Bačmaga ; Adrijan Barić ; Fabio Pareschi ; Riccardo Rovatti ; Gianluca Setti

engleski

Impact of the Spread-Spectrum Technique on the Higher-Order Harmonics and Radiated Emissions of a Synchronous Buck Converter

Switched-mode power converters generate electromagnetic emissions which may violate the limits specified in the regulations. Spread- spectrum is an effective technique for reducing the electromagnetic interference of switching devices. The reduction of the magnitude of the first harmonic by the spread-spectrum technique is mainly in focus in the literature. In this paper, the impact on the higher-order harmonics and on the radiated emissions is analyzed. A non- regulated synchronous buck converter is used as a device under test. The radiated emissions of the converter are calculated from the measurements performed by a transverse electromagnetic cell and a hybrid coupler. The measurements are performed for different values of the parameters of the spread-spectrum technique and a reduction of up to 5.7 dB is obtained.

electromagnetic compatibility ; electromagnetic interference ; power conversion ; switched-mode power supply ; transverse electromagnetic cell

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

13-16.

2018.

objavljeno

10.1109/NGCAS.2018.8572290

Podaci o matičnoj publikaciji

Podaci o skupu

predavanje

20.11.2018-20.11.2018

Valletta, Malta

Povezanost rada

nije evidentirano

Poveznice